Heating, Ventilation, and Air Conditioning provides every day clean and comfortable indoor environments. Many industries require specific regulatory temperatures and air quality in order to maintain their products. Various different types of sensors help to regulate and ensure these environments. Temperature is an essential sensor used for proper heating and cooling from large industrial environments to small and medium sized residential environments. The most common sensor for these applications is RTD sensors as well as 4-20ma transmitters. However, stick on and clip on thermocouples can also be used for temporary and testing purposes. If you have a specific design for your application we can accommodate and build it at competitive prices.

Common Applications:

  • Air Conditioning
  • Heating
  • Ventilation
  • Duct temperature control
  • Piping temperature control
HVAC Bolt on Surface Rtd Probe100/1000 Ohm Industrial Rtd ProbeHVAC 100/1000 Ohm Rtd ProbeHigh Temp 100 Ohm Rtd ProbeSelf-Adhesive Flex-Wire ProbeClip on Surface ProbeSHOW ALL

HVAC Bolt-on Surface RTD Probe – HV0093A

Specification/Model HV0093A  HV0093A-1K
Element 100 Ohm/1000 Ohm Pt/385
Temp. Range Class A Tolerance : -58°F ~ 425°F
RTD Styles Aluminum Bold On Housing 1x.812″ Mount
Wire Extensions FEP
Wire Leads 3-Wire
Wire Length 4 Feet
Connection Stripped Leads

100/1000 Ohm Industrial RTD Probe – HV0177I

Specification/Model HV0177I
Element 100 Ohm/1000 Ohm Pt/385
Temp. Range Class A Tolerance : -58°F ~ 425°F
RTD Styles NPT Nipple & Aluminum Housing (Industrial)
Sensor O.D. .250 (1/4″) Diameter Fixed Sheath / Spring Loaded
Wire Extensions N/A
Wire Leads 3-Wire
“A” Dimension 4″ – 6″ – 12″ – 24″
“B” Dimension 0′
Connection N/A

HVAC 100/1000 Ohm RTD Probe – HV0473T

Specification/Model HV0473T HV0473T-1K
Element 100 Ohm/1000 Ohm Pt/385
Temp. Range Class A Tolerance : -58°F ~ 425°F
RTD Styles None (Tube & Wire)
Sensor O.D. .188 (3/16″) Diameter
Wire Extensions FEP
Wire Leads 3-Wire
“A” Dimension 2″ – 4″ – 8″ – 12″
“B” Dimension 3′
Connection Stripped Leads

High Temp 100 Ohm RTD Probe – HV0837T

Specification/Model HV0837T
Element High Temp Element 100 Ohm Pt/385
Temp. Range Class A Tolerance : -58°F ~ 425°F       Class B Tolerance : -94°F ~ 900°F
RTD Styles None (Tube & Wire)
Sensor O.D. .188 (3/16″) Diameter
Wire Extensions Fiberglass
Wire Leads 3-Wire
“A” Dimension 2″ – 4″ – 8″ – 12″
“B” Dimension 3′
Connection Stripped Leads

Self-Adhesive Flex-Wire Probe – HV1173-3P

Part Number HV1173-3PK HV1173-3PJ HV1173-3PT
Sensor Type Type K (Chromel/Alumel) Type J (Iron/constantan) Type T (Copper/constantan)
Temp. Range Up to 400°F
Wire Fauge 30 AWG
Junction Type Insulated with 1′ x 2″ Kapton Tape
Wire Kapton
Wire Length 5′, 10′
Terminal Mini Plug

Clip on Surface Probe – HV02112

Part Number HV02112K HV02112J HV02112T
Sensor Type Type K (Chromel/Alumel) Type J (Iron/constantan) Type T (Copper/constantan)
Temp. Range Up to 900°F
Wire Fauge 24 AWG
Junction Type Exposed (with 2″ Alligator Clip)
Wire Fiberglass with Stainless Steel Overbraid
Wire Length 5′, 10′
Terminal Mini Plug